The Schneider Electric Easy UPS 3 Series is an easy-to-install, easy-to-connect, easy-to-use, and easy-to-service 10-200 kVA 3 phase UPS ideal for small and medium businesses, data centers, and other mission critical applications. The Schneider Electric Easy UPS 3 Series brings predictability to utility costs by delivering up to 96 percent efficiency in double conversion mode and up to 99 percent efficiency in energy-saving ECO mode, thanks to its advanced product features, competitive specifications, and robust electrical design. It is exceptionally easy to install, connect, operate, maintain, and service, making it ideal for a wide range of small and medium business applications. This EcoStruxure™ Ready UPS features a wide operating temperature range and strong overload protection, all in a compact and lightweight footprint. Start-up service* optimizes your system’s performance, quality, and safety. The Easy UPS 3 Series is the easy choice for your business continuity in the data center or electrical room.
Specifications for UPS :
Main | |
Main Input Voltage | 400 V 3 phases |
Other Input Voltage | 380 V |
415 V | |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V |
415 V | |
Rated power in W | 40 kW |
Rated power in VA | 40 kVA |
Provided equipment | Dust filter |
Installation guide | |
Physical | |
Colour | White (RAL 9003) |
Height | 77 cm |
Width | 25 cm |
Depth | 90 cm |
Net weight | 70 kg |
USB compatible | Yes |
Input | |
Maximum input current | 73 A |
Load power factor | 0.9 leading to 0.9 lagging |
Input Power Factor at Full Load | 0.99 |
Input voltage limits | 304...477 V |
Network frequency | 45...65 Hz |
Output | |
Maximum configurable power in VA | 40 kVA |
Maximum configurable power in W | 40 kW |
Output frequency | 50 Hz sync to mains |
60 Hz sync to mains | |
Harmonic distortion | Less than 3 % |
Output harmonic distortion | < 3% linear load |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
UPS type | Double conversion online |
Bypass type | Built-in maintenance bypass |
Crest factor | 03:01 |
Conformance | |
Product certifications | CE |
EAC | |
RCM | |
Environmental | |
ambient air temperature for operation | 0…40 °C |
Relative humidity | 0…95 % non-condensing |
Operating altitude | 0...3281 ft |
Ambient air temperature for storage | -15…40 °C |
Storage Relative Humidity | 0…95 % non-condensing |
Storage altitude | 0.00…14999.82 m |
Acoustic level | 63 dBA |
heat dissipation | 1880 Btu/h |
IP degree of protection | IP20 |
Batteries & Runtime | |
Battery type | External battery system |
Maximum short-circuit current | 10 kA |
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 101.5 cm |
Package 1 Width | 105 cm |
Package 1 Length | 40 cm |
Package 1 Weight | 86 kg |
Contractual warranty | |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |